JUMBO FireWALL 102/60/6m

JUMBO Fire Resistant Drywall Partition System for 60 Minute Fire Resistance up to Six Metres High

This is a non-loadbearing high performance 60 Minute Fire Resistant Drywall using  one 12mm and one 15mm Fire Resistant JUMBO Board on either side of the 102mm Stud and 103mm Track, giving the overall wall thickness of 156mm and applicable for a FireWALL up to six metres in height. The framework / Stud spacings are at 400mm centres and an H-Track / Transom is installed at three metre height allowing for the use of three metre Studs and JUMBO Boards.

Test Results:-

The JUMBO FireWALL system met the criteria for a 60 minute non-load bearing wall system when tested in accordance with SANS 10177-2 test protocol.

The performance of the system satisfied all the criteria for Stability, Integrity and Insulation for 60 minutes.

Classification is as follows:-

SANS 10177-2 – FR60 (Non-load bearing)

Stability (R) – 60 minutes

Integrity (E) – 120 minutes

Insulation (I) – 120 minutes